HFCAS OpenIR
Design of infrared radiation diagnostic calorimeter for the prototype radio frequency driven negative ion source for neutral beam injection
Xu, Yongjian; Xie, Yahong; Jiang, Caichao; Wei, Jianglong; Li, Jun; Gu, Yuming; Yu, Ling; Liang, Lizhen; Zhao, Yuanzhe; Tao, Liang; Xie, Yuanlai; Hu, Chundong
2020-04-01
发表期刊REVIEW OF SCIENTIFIC INSTRUMENTS
ISSN0034-6748
摘要

In order to study the generation and extraction of negative ions for neutral beam injection application, a prototype radio frequency driven negative ion source and the corresponding test bench are under construction at the Institute of Plasma Physics, Chinese Academy of Sciences. A new design of infrared radiation diagnostic calorimeter for testing beam characteristics is put forward. Compared with the conventional calorimeter, the calorimeter adopts the block structure (8 x 28 tungsten hexahedron blocks) and modularization design (4 modules), so it has higher precision and good scalability. The thermal performance of the calorimeter is assessed using a finite element method. Simulation results show that the design can be achieved to operate in the stable-state mode at the maximum thermal flux 6.45 MW/m(2) and meet the full requirement of beam diagnosis.

DOI10.1063/1.5130717
收录类别SCI
语种英语
资助项目National Key R&D Program of China[2017YFE0300103] ; National Natural Science Foundation of China[11975262] ; National Natural Science Foundation of China[11905248]
项目资助者National Key R&D Program of China ; National Natural Science Foundation of China
WOS研究方向Instruments & Instrumentation ; Physics
WOS类目Instruments & Instrumentation ; Physics, Applied
WOS记录号WOS:000523473200001
出版者AMER INST PHYSICS
引用统计
文献类型期刊论文
条目标识符http://ir.hfcas.ac.cn:8080/handle/334002/103476
专题中国科学院合肥物质科学研究院
通讯作者Xu, Yongjian
作者单位Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Peoples R China
第一作者单位中科院等离子体物理研究所
通讯作者单位中科院等离子体物理研究所
推荐引用方式
GB/T 7714
Xu, Yongjian,Xie, Yahong,Jiang, Caichao,et al. Design of infrared radiation diagnostic calorimeter for the prototype radio frequency driven negative ion source for neutral beam injection[J]. REVIEW OF SCIENTIFIC INSTRUMENTS,2020.
APA Xu, Yongjian.,Xie, Yahong.,Jiang, Caichao.,Wei, Jianglong.,Li, Jun.,...&Hu, Chundong.(2020).Design of infrared radiation diagnostic calorimeter for the prototype radio frequency driven negative ion source for neutral beam injection.REVIEW OF SCIENTIFIC INSTRUMENTS.
MLA Xu, Yongjian,et al."Design of infrared radiation diagnostic calorimeter for the prototype radio frequency driven negative ion source for neutral beam injection".REVIEW OF SCIENTIFIC INSTRUMENTS (2020).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Design of infrared r(2314KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Xu, Yongjian]的文章
[Xie, Yahong]的文章
[Jiang, Caichao]的文章
百度学术
百度学术中相似的文章
[Xu, Yongjian]的文章
[Xie, Yahong]的文章
[Jiang, Caichao]的文章
必应学术
必应学术中相似的文章
[Xu, Yongjian]的文章
[Xie, Yahong]的文章
[Jiang, Caichao]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Design of infrared radiation diagnostic.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。