HFCAS OpenIR
A simple replacement of tungsten filament hot cathodes by DC heated LaB6 rod and its noise characteristics with laser-induced fluorescence
Jiang, Di1; Yip, Chi-Shung1; Zhang, Wei1; Jin, Chen-yao1,2; Xu, Guo-Sheng1; Wang, Liang1
2021-12-01
发表期刊REVIEW OF SCIENTIFIC INSTRUMENTS
ISSN0034-6748
通讯作者Yip, Chi-Shung(csyip@ipp.ac.cn)
摘要Hot cathode discharges are common plasma sources for fundamental plasma physics studies and other applications due to their quiescent and relatively simple properties, and tungsten filaments are commonly used for the ease of heating them. Recently, tungsten filaments are increasingly being replaced by less luminous alternatives, such as barium oxide or lanthanum hexaboride. These materials can emit electrons at temperatures close to 1000 K lower than tungsten, greatly reducing their blackbody radiations. This results in significant improvement in signal recovery for active spectral diagnostic, such as laser-induced fluorescence. However, these less luminous cathodes often come in vastly more complicated designs than those of tungsten hot cathodes and are much more expensive to procure and difficult to operate. In this paper, we present a simple, low cost direct current heated design of a LaB6 cathode that is manufactured at suitable dimensions and make a comparison of the laser-induced fluorescence (LIF) signal-to-noise ratio of this LaB6 hot cathode discharge with that of a typical tungsten filament discharge, revealing that LaB6 has, indeed, an improved LIF signal-to-noise ratio compared with the tungsten filament. Published under an exclusive license by AIP Publishing.
DOI10.1063/5.0071496
关键词[WOS]VELOCITY ; TRANSPORT
收录类别SCI
语种英语
WOS研究方向Instruments & Instrumentation ; Physics
WOS类目Instruments & Instrumentation ; Physics, Applied
WOS记录号WOS:000758030200004
出版者AIP Publishing
引用统计
被引频次:5[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.hfcas.ac.cn:8080/handle/334002/127540
专题中国科学院合肥物质科学研究院
通讯作者Yip, Chi-Shung
作者单位1.Chinese Acad Sci, Hefei Inst Phys Sci, Inst Plasma Phys, Hefei 230031, Peoples R China
2.Univ Sci & Technol China, Hefei 230026, Peoples R China
推荐引用方式
GB/T 7714
Jiang, Di,Yip, Chi-Shung,Zhang, Wei,et al. A simple replacement of tungsten filament hot cathodes by DC heated LaB6 rod and its noise characteristics with laser-induced fluorescence[J]. REVIEW OF SCIENTIFIC INSTRUMENTS,2021,92.
APA Jiang, Di,Yip, Chi-Shung,Zhang, Wei,Jin, Chen-yao,Xu, Guo-Sheng,&Wang, Liang.(2021).A simple replacement of tungsten filament hot cathodes by DC heated LaB6 rod and its noise characteristics with laser-induced fluorescence.REVIEW OF SCIENTIFIC INSTRUMENTS,92.
MLA Jiang, Di,et al."A simple replacement of tungsten filament hot cathodes by DC heated LaB6 rod and its noise characteristics with laser-induced fluorescence".REVIEW OF SCIENTIFIC INSTRUMENTS 92(2021).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Jiang, Di]的文章
[Yip, Chi-Shung]的文章
[Zhang, Wei]的文章
百度学术
百度学术中相似的文章
[Jiang, Di]的文章
[Yip, Chi-Shung]的文章
[Zhang, Wei]的文章
必应学术
必应学术中相似的文章
[Jiang, Di]的文章
[Yip, Chi-Shung]的文章
[Zhang, Wei]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。