HFCAS OpenIR
Fast-sweeping Langmuir probes: what happens to the I -V trace when sweeping frequency is higher than the ion plasma frequency?
Jin, Chenyao1,2; Yip, Chi-shung1; Zhang, Wei1; Jiang, Di1; Xu, Guosheng1
2022-02-01
发表期刊PLASMA SCIENCE & TECHNOLOGY
ISSN1009-0630
通讯作者Yip, Chi-shung(csyip@ipp.ac.cn) ; Zhang, Wei(zhangwei@ipp.ac.cn)
摘要Limited particle transit time is one of several limiting factors which determine the maximum temporal resolution of a Langmuir probe. In this work, we have revisited the known fast sweep Langmuir probe techniques in a uniform, quiescent multi-dipole confined hot cathode discharge with two operation scenarios: one in which the probe sweeping frequency f (sweep) is much lower than the ion plasma frequency f (pi), another one where f (sweep) is much greater than f (pi), respectively. This allows investigation into the effect of limited ion-motion on I-V traces. Serious distortions of I-V traces at high frequencies, previously claimed to be an ion-motion limitation effect, were not found unless shunt resistance is sufficiently high, despite a f (sweep)/f (pi) ratio of similar to 3. On the other hand, evidences of sheath capacitance on the I-V traces have been observed. Distortions of I-V traces qualitatively agree with predictions of sheath capacitance response to the sweeping voltage. Additionally, techniques in fast sweep Langmuir probe are briefly discussed. The comparison between the high-speed dual Langmuir probe (HDLP) and the single probe setup shows that the capacitive response can be removed via subtracting a leakage current for the single probe setup almost as effectively as using the HDLP setup, but the HDLP setup does remain advantageous in its facilitation of better recovery of weak current signal commonly in low density plasma.
关键词high speed diagnostics time resolved diagnostics Langmuir probe
DOI10.1088/2058-6272/ac41c0
关键词[WOS]SHEATH ; KHZ
收录类别SCI
语种英语
资助项目National Natural Science Foundation of China[11875285] ; CAS Key Research Program of Frontier Sciences[QYZDB-SSW-SLH001] ; Chinese Academy of Science Hundred Youth Talent Program
项目资助者National Natural Science Foundation of China ; CAS Key Research Program of Frontier Sciences ; Chinese Academy of Science Hundred Youth Talent Program
WOS研究方向Physics
WOS类目Physics, Fluids & Plasmas
WOS记录号WOS:000756012200001
出版者IOP Publishing Ltd
引用统计
被引频次:1[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.hfcas.ac.cn:8080/handle/334002/127674
专题中国科学院合肥物质科学研究院
通讯作者Yip, Chi-shung; Zhang, Wei
作者单位1.Chinese Acad Sci, Inst Plasma Phys, Hefei Inst Phys Sci, Hefei 230031, Peoples R China
2.Univ Sci & Technol China, Hefei 230026, Peoples R China
第一作者单位中科院等离子体物理研究所
通讯作者单位中科院等离子体物理研究所
推荐引用方式
GB/T 7714
Jin, Chenyao,Yip, Chi-shung,Zhang, Wei,et al. Fast-sweeping Langmuir probes: what happens to the I -V trace when sweeping frequency is higher than the ion plasma frequency?[J]. PLASMA SCIENCE & TECHNOLOGY,2022,24.
APA Jin, Chenyao,Yip, Chi-shung,Zhang, Wei,Jiang, Di,&Xu, Guosheng.(2022).Fast-sweeping Langmuir probes: what happens to the I -V trace when sweeping frequency is higher than the ion plasma frequency?.PLASMA SCIENCE & TECHNOLOGY,24.
MLA Jin, Chenyao,et al."Fast-sweeping Langmuir probes: what happens to the I -V trace when sweeping frequency is higher than the ion plasma frequency?".PLASMA SCIENCE & TECHNOLOGY 24(2022).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Jin, Chenyao]的文章
[Yip, Chi-shung]的文章
[Zhang, Wei]的文章
百度学术
百度学术中相似的文章
[Jin, Chenyao]的文章
[Yip, Chi-shung]的文章
[Zhang, Wei]的文章
必应学术
必应学术中相似的文章
[Jin, Chenyao]的文章
[Yip, Chi-shung]的文章
[Zhang, Wei]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。