HFCAS OpenIR
Ultrashort Pulse Reflectometry (USPR) diagnostic for EAST
Domier, C. W.1; Zhu, Y.1; Pereira, R. J.1; Steer-Furderer, J.1; Li, X.2; Chen, R.2; Xu, G.2; Sun, P.2; Luhmann, N. C., Jr.1
2022-02-01
发表期刊JOURNAL OF INSTRUMENTATION
ISSN1748-0221
通讯作者Domier, C. W.(cwdomier@ucdavis.edu)
摘要Ultrashort Pulse Reflectometry (USPR) is a plasma diagnostic technique involving the propagation of ultrashort duration (similar to few nsec) chirps which contain frequency components spanning large portions of the plasma density profile. Upon reflection, each frequency component reflects from a distinct density layer. The reflected wave packet is down-converted and passed through a multi-channel filter bank, with time-of-flight (TOF) measurements made on each of the filtered wave packets which are then used to reconstruct the electron density profile. Applied previously to the Sustained Spheromak Physics Experiment, UC Davis is updating this technique with higher power (>10X) sources, enhanced channel counts, and high speed customized TOF electronics. A 32 channel USPR system is being developed for the Experimental Advanced Superconducting Tokamak (EAST) device with frequencies spanning 52 to 92 GHz, reflecting from the right-hand plasma cut-off layer. The system will employ three monostatic transmit/receive horns each covering a different waveguide band. Each of the two higher frequency bands will have 8 distinct frequency channels, with the lowest frequency band, spanning 52 to 65 GHz, to have 16 receiver channels to better resolve the EAST scrape-off layer. With a pulse repetition rate of 1 MHz and simultaneous acquisition of all 32 TOF signals, electron density profiles may be obtained with time resolutions of as short as 3-6 mu sec.
关键词Plasma diagnostics - interferometry, spectroscopy and imaging Analogue electronic circuits Nuclear instruments and methods for hot plasma diagnostics
DOI10.1088/1748-0221/17/02/C02010
关键词[WOS]DENSITY PROFILE
收录类别SCI
语种英语
资助项目National Fusion Energy Program of China[2019FE03030000]
项目资助者National Fusion Energy Program of China
WOS研究方向Instruments & Instrumentation
WOS类目Instruments & Instrumentation
WOS记录号WOS:000791423900002
出版者IOP Publishing Ltd
引用统计
被引频次:1[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.hfcas.ac.cn:8080/handle/334002/131520
专题中国科学院合肥物质科学研究院
通讯作者Domier, C. W.
作者单位1.Univ Calif Davis, Dept Elect & Comp Engn, 1 Shields Ave, Davis, CA 95616 USA
2.Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Peoples R China
推荐引用方式
GB/T 7714
Domier, C. W.,Zhu, Y.,Pereira, R. J.,et al. Ultrashort Pulse Reflectometry (USPR) diagnostic for EAST[J]. JOURNAL OF INSTRUMENTATION,2022,17.
APA Domier, C. W..,Zhu, Y..,Pereira, R. J..,Steer-Furderer, J..,Li, X..,...&Luhmann, N. C., Jr..(2022).Ultrashort Pulse Reflectometry (USPR) diagnostic for EAST.JOURNAL OF INSTRUMENTATION,17.
MLA Domier, C. W.,et al."Ultrashort Pulse Reflectometry (USPR) diagnostic for EAST".JOURNAL OF INSTRUMENTATION 17(2022).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Domier, C. W.]的文章
[Zhu, Y.]的文章
[Pereira, R. J.]的文章
百度学术
百度学术中相似的文章
[Domier, C. W.]的文章
[Zhu, Y.]的文章
[Pereira, R. J.]的文章
必应学术
必应学术中相似的文章
[Domier, C. W.]的文章
[Zhu, Y.]的文章
[Pereira, R. J.]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。