HFCAS OpenIR
Upgrade of the magnetic diagnostic system for restart of HT-6M operation
Chen, Li-Xing1,2; Shen, Biao1; Chen, Da-Long1; Luo, Zheng-Ping1; Zhang, Zu-Chao1; Chen, Ying1; Wang, Yong1; Qian, Jin-Ping1
2022-11-01
发表期刊CHINESE PHYSICS B
ISSN1674-1056
通讯作者Chen, Da-Long(cdalong@ipp.ac.cn) ; Luo, Zheng-Ping(zhpluo@ipp.ac.cn)
摘要The HT-6M tokamak at the Thailand Institute of Nuclear Technology has been restarted. In order to ensure the smooth breakdown of plasma and obtain plasma discharge parameters, optimization of the poloidal field coils and upgrade of the magnetic diagnostics are described in this article. A perfect null field (stray field in the main chamber < 10 G) is obtained using an ohmic heating field. To obtain important information about the plasma, an external magnetic diagnostics system is designed and calibrated, including a Rogowski coil (measuring plasma current), a magnetic probe (measuring external field), diamagnetic loops (measuring beta (p)) and so on. In order to realize high-frequency signal measurement and transmission, a series of frequency responses with the magnetic probe and transmission line are tested. Later, to verify the null field, a fitting code is developed to reconstruct the stray field in the vacuum chamber based on magnetic probe measurements and flux loops. The results show that the error is within 1.5%. This indicates the accuracy of the magnetic measurement system and ensures the preparation for the breakdown of plasma.
关键词HT-6M null field magnetic measurement high frequency calibration
DOI10.1088/1674-1056/ac7f93
关键词[WOS]RECONSTRUCTION ; EQUILIBRIUM
收录类别SCI
语种英语
资助项目National MCF Energy Research and Development Program of China ; National Natural Science Foundation of China ; Comprehensive Research Facility for Fusion Technology Program of China ; [2018YFE0302100] ; [2018YFE0301105] ; [11875291] ; [2018-000052-73-01-001228]
项目资助者National MCF Energy Research and Development Program of China ; National Natural Science Foundation of China ; Comprehensive Research Facility for Fusion Technology Program of China
WOS研究方向Physics
WOS类目Physics, Multidisciplinary
WOS记录号WOS:000889806700001
出版者IOP Publishing Ltd
引用统计
文献类型期刊论文
条目标识符http://ir.hfcas.ac.cn:8080/handle/334002/131641
专题中国科学院合肥物质科学研究院
通讯作者Chen, Da-Long; Luo, Zheng-Ping
作者单位1.Chinese Acad Sci, Inst Plasma Phys, Hefei Inst Phys Sci, Hefei 230026, Peoples R China
2.Univ Sci & Technol China, Hefei 230026, Peoples R China
第一作者单位中科院等离子体物理研究所
通讯作者单位中科院等离子体物理研究所
推荐引用方式
GB/T 7714
Chen, Li-Xing,Shen, Biao,Chen, Da-Long,et al. Upgrade of the magnetic diagnostic system for restart of HT-6M operation[J]. CHINESE PHYSICS B,2022,31.
APA Chen, Li-Xing.,Shen, Biao.,Chen, Da-Long.,Luo, Zheng-Ping.,Zhang, Zu-Chao.,...&Qian, Jin-Ping.(2022).Upgrade of the magnetic diagnostic system for restart of HT-6M operation.CHINESE PHYSICS B,31.
MLA Chen, Li-Xing,et al."Upgrade of the magnetic diagnostic system for restart of HT-6M operation".CHINESE PHYSICS B 31(2022).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Chen, Li-Xing]的文章
[Shen, Biao]的文章
[Chen, Da-Long]的文章
百度学术
百度学术中相似的文章
[Chen, Li-Xing]的文章
[Shen, Biao]的文章
[Chen, Da-Long]的文章
必应学术
必应学术中相似的文章
[Chen, Li-Xing]的文章
[Shen, Biao]的文章
[Chen, Da-Long]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。