Study on Hydrogen Fluoride at High Temperature Detection Method with Temperature Correction Based on Laser Technology
He Ying1,2; Zhang Yu-jun1; You Kun1; Gao Yan-wei1; Chen Chen1; Liu Wen-qing1
2017-03-01
发表期刊SPECTROSCOPY AND SPECTRAL ANALYSIS
摘要Hydrogen fluoride(HF) is one of the important character gases for fault diagnosis of gas insulation switch (GIS) in the system of substation equipment. The high-accuracy, fast- response and real-time detection method of HF is a focus in industrial and environmental fields. In this research, the HF detection experiment system was set up at first based on laser absorption spectroscopy technology combined with anti-corrosion multiple reflection cell made by monel steel. Moreover, the laser absorption spectral characteristics of HF at different temperature were analyzed, then the coefficient partition function curve and absorption linestrength curve according to the distribution function coefficient in HITRAN database were studied. As the most important work, the concentration inversion algorithm was designed here with HF character spectrum analysis and temperature parameter correction method for accurate concentration inversion after the basic study. At last, the continuous experimental results were obtained by HF sample gases of different concentration considerating the temperature characteristic of the multiple reflection cell. When the multiple reflection cell was heat and stay stably, the biggest detection error of concentration inversion was 5. 33% and 5. 87% at 313 and 323 K respectively without temperature correction, and that was 1.20% and 1. 47% respectively after temperature correction. By continuous detection and culculation, the detection limit is 8.7 X 10(-5) mmol . mor(-1) at 323 K which is a little higher than 6.3 X 10(-5) mmol . mol(-1) at 290 K(20 m optical length). Although the detection error with temperature correction at high temperature was higher than it at room temperature, the results show that it was lower than that without correction at the same temperature. It was verified that the this spectrum detection method and concentration inversion algorithm works stably and reliably, so this technology could realize HF real-time monitoring demand in chemical production field and it will provide the effective technical support in gas emission regulation in safety and environment protection for our country.
文章类型Article
关键词Laser Absorption Spectroscopy Temperature Correction Concentration Inversion Algorithm Multiple Reflection Cell Hydrogen Fluoride
WOS标题词Science & Technology ; Technology
DOI10.3964/j.issn.1000-0593(2017)03-0964-07
收录类别SCI
语种英语
项目资助者National Key Scientific Instrument and Equipment Development Projects(2012YQ22011902) ; National Key Scientific Instrument and Equipment Development Projects(2012YQ22011902) ; National Key Scientific Instrument and Equipment Development Projects(2012YQ22011902) ; National Key Scientific Instrument and Equipment Development Projects(2012YQ22011902) ; 863 National High Technology Research and Development Program of China(2014AA06A503) ; 863 National High Technology Research and Development Program of China(2014AA06A503) ; 863 National High Technology Research and Development Program of China(2014AA06A503) ; 863 National High Technology Research and Development Program of China(2014AA06A503)
WOS研究方向Spectroscopy
WOS类目Spectroscopy
WOS记录号WOS:000397352600053
引用统计
被引频次:2[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.hfcas.ac.cn:8080/handle/334002/31756
专题中科院安徽光学精密机械研究所
作者单位1.Chinese Acad Sci, Key Lab Environm Opt & Technol, Anhui Inst Opt & Fine Mech, Hefei 230031, Peoples R China
2.Univ Sci & Technol China, Hefei 230026, Peoples R China
推荐引用方式
GB/T 7714
He Ying,Zhang Yu-jun,You Kun,et al. Study on Hydrogen Fluoride at High Temperature Detection Method with Temperature Correction Based on Laser Technology[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS,2017,37(3):964-970.
APA He Ying,Zhang Yu-jun,You Kun,Gao Yan-wei,Chen Chen,&Liu Wen-qing.(2017).Study on Hydrogen Fluoride at High Temperature Detection Method with Temperature Correction Based on Laser Technology.SPECTROSCOPY AND SPECTRAL ANALYSIS,37(3),964-970.
MLA He Ying,et al."Study on Hydrogen Fluoride at High Temperature Detection Method with Temperature Correction Based on Laser Technology".SPECTROSCOPY AND SPECTRAL ANALYSIS 37.3(2017):964-970.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
基于激光技术结合温度修正的高温HF气体检(974KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[He Ying]的文章
[Zhang Yu-jun]的文章
[You Kun]的文章
百度学术
百度学术中相似的文章
[He Ying]的文章
[Zhang Yu-jun]的文章
[You Kun]的文章
必应学术
必应学术中相似的文章
[He Ying]的文章
[Zhang Yu-jun]的文章
[You Kun]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 基于激光技术结合温度修正的高温HF气体检测方法研究_英文_何莹.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。