HFCAS OpenIR  > 中科院等离子体物理研究所
Design of a Data Acquisition System in the Cooling Test for ITER Radial X-Ray Camera
Zhang, Bin1,2; Li, Shi1; Zhang, Sheng1,2; Chen, Yebin1; Hu, Liqun1
2017-07-01
Source PublicationFUSION SCIENCE AND TECHNOLOGY
Volume72Issue:1Pages:91-98
AbstractThe Radial X-ray camera (RXC) is a diagnostic for the ITER tokamak. During baking and operation of ITER, the detector environment temperature will be up to 240 degrees C, whereas the detectors must be kept below 70 degrees C. Therefore, cooling of the detectors mounted in the camera is critical and necessary. In order to verify the effect of gas cooling for RXC detectors, a relevant test has been designed. Since the outcome of this test will be the supply of the RXC cooling system, the ITER Instrument and Control strategy was selected. Therefore, a Data Acquisition (DAQ) system was developed based on the Experimental Physics and Industrial Control System (EPICS) framework, which implements functions for real-time data acquisition, temperature control, supervision, and archiving. Moreover, it is easy to configure control information according to user requirements. Also, some linear devices were used in the reconfiguration of EPICS. This technical note presents the entire architecture of the DAQ system and the details on the design of EPICS. The system has been implemented, and has provided reliable data for the experiment.
SubtypeArticle
KeywordData Acquisition Cooling Test Radial X-ray Camera
WOS HeadingsScience & Technology ; Technology
Funding OrganizationInstitute of Plasma Physics, Chinese Academy of Sciences ; Institute of Plasma Physics, Chinese Academy of Sciences ; Institute of Plasma Physics, Chinese Academy of Sciences ; Institute of Plasma Physics, Chinese Academy of Sciences
DOI10.1080/15361055.2017.1319717
WOS KeywordCODAC
Indexed BySCI
Language英语
Funding OrganizationInstitute of Plasma Physics, Chinese Academy of Sciences ; Institute of Plasma Physics, Chinese Academy of Sciences ; Institute of Plasma Physics, Chinese Academy of Sciences ; Institute of Plasma Physics, Chinese Academy of Sciences
WOS Research AreaNuclear Science & Technology
WOS SubjectNuclear Science & Technology
WOS IDWOS:000405789900008
Citation statistics
Document Type期刊论文
Identifierhttp://ir.hfcas.ac.cn:8080/handle/334002/33536
Collection中科院等离子体物理研究所
Affiliation1.Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China
2.Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China
Recommended Citation
GB/T 7714
Zhang, Bin,Li, Shi,Zhang, Sheng,et al. Design of a Data Acquisition System in the Cooling Test for ITER Radial X-Ray Camera[J]. FUSION SCIENCE AND TECHNOLOGY,2017,72(1):91-98.
APA Zhang, Bin,Li, Shi,Zhang, Sheng,Chen, Yebin,&Hu, Liqun.(2017).Design of a Data Acquisition System in the Cooling Test for ITER Radial X-Ray Camera.FUSION SCIENCE AND TECHNOLOGY,72(1),91-98.
MLA Zhang, Bin,et al."Design of a Data Acquisition System in the Cooling Test for ITER Radial X-Ray Camera".FUSION SCIENCE AND TECHNOLOGY 72.1(2017):91-98.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Zhang, Bin]'s Articles
[Li, Shi]'s Articles
[Zhang, Sheng]'s Articles
Baidu academic
Similar articles in Baidu academic
[Zhang, Bin]'s Articles
[Li, Shi]'s Articles
[Zhang, Sheng]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Zhang, Bin]'s Articles
[Li, Shi]'s Articles
[Zhang, Sheng]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.