HFCAS OpenIR  > 中科院强磁场科学中心
Comparison of 12 Quadrature Birdcage Coils with Different Leg Shapes at 9.4 T
Xu, Yongfeng1,2; Wen, Qingqing1,3
2017-09-01
Source PublicationAPPLIED MAGNETIC RESONANCE
Volume48Issue:9Pages:901-909
AbstractThe purpose of this study was to analyse the relationship between the radio frequency (RF) coil performance and conductor surface shape for ultra-high field (UHF) magnetic resonance imaging. Twelve different leg-shaped quadrature birdcage coils were modeled and built, e.g., 4 mm-width-leg conventional birdcage coil, 7 mm-width-leg conventional birdcage, 10 mm-width-leg conventional birdcage coil, 13 mm-width-leg conventional birdcage coil, inside arc-shape-leg birdcage coil, outward arc-shape-leg birdcage coil, inside right angle-shape-leg birdcage coil, outward right angle-shape-leg birdcage coil, vertical 4 mm-width-leg vertical birdcage, 6 mm-width-leg vertical birdcage, 8 mm-width-leg vertical birdcage and 10 mm-width-leg vertical birdcage. Studies were carried out in both electromagnetic simulations with finite element method as well as in vitro saline phantom experiments at 9.4 T. Both the results of simulation and experiment showed that conventional birdcage coil produces the highest signal-to-noise ratio (SNR) while the vertical birdcage coil produces the most homogeneous RF magnetic (B (1)) field at UHF. For conventional birdcage coils, as well as the vertical birdcage coils, only the proper width of legs results in the best performance (e.g., B (1) homogeneous and SNR). For vertical birdcage coils, the wider the leg size, the higher RF magnetic (B (1)) field intensity distribution.
SubtypeArticle
WOS HeadingsScience & Technology ; Physical Sciences ; Technology
DOI10.1007/s00723-017-0920-y
WOS KeywordHYPERPOLARIZED C-13
Indexed BySCI
Language英语
WOS Research AreaPhysics ; Spectroscopy
WOS SubjectPhysics, Atomic, Molecular & Chemical ; Spectroscopy
WOS IDWOS:000407561100004
Citation statistics
Document Type期刊论文
Identifierhttp://ir.hfcas.ac.cn:8080/handle/334002/33617
Collection中科院强磁场科学中心
Affiliation1.Chinese Acad Sci, High Field Magnet Lab, Hefei 230031, Peoples R China
2.Univ Sci & Technol China, Hefei 230026, Peoples R China
3.Univ Chinese Acad Sci, Beijing 10010, Peoples R China
Recommended Citation
GB/T 7714
Xu, Yongfeng,Wen, Qingqing. Comparison of 12 Quadrature Birdcage Coils with Different Leg Shapes at 9.4 T[J]. APPLIED MAGNETIC RESONANCE,2017,48(9):901-909.
APA Xu, Yongfeng,&Wen, Qingqing.(2017).Comparison of 12 Quadrature Birdcage Coils with Different Leg Shapes at 9.4 T.APPLIED MAGNETIC RESONANCE,48(9),901-909.
MLA Xu, Yongfeng,et al."Comparison of 12 Quadrature Birdcage Coils with Different Leg Shapes at 9.4 T".APPLIED MAGNETIC RESONANCE 48.9(2017):901-909.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Xu, Yongfeng]'s Articles
[Wen, Qingqing]'s Articles
Baidu academic
Similar articles in Baidu academic
[Xu, Yongfeng]'s Articles
[Wen, Qingqing]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Xu, Yongfeng]'s Articles
[Wen, Qingqing]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.