Institutional Repository of Chinese Academy of Sciences, Institute of Plasma Physics, Hefei 230031, Anhui, Peoples R China
Design and Test of Irradiation-Related Components in ITER Radial X-Ray Camera | |
Hu, L.; Cao, H.; Zhao, J.; Niu, L.; Chen, Y.; Zhou, N.; Zhan, J.; Yu, H.; Chen, K.; Li, S.; Sheng, X.; Shen, J.; Qin, S.; Feng, C.; Ge, J.; Zhang, B.; Zhang, S. | |
2018-09-01 | |
发表期刊 | IEEE TRANSACTIONS ON NUCLEAR SCIENCE |
ISSN | 0018-9499 |
通讯作者 | Cao, H.(caohr@ipp.ac.cn) |
摘要 | International Thermonuclear Experimental Reactor radial X-ray camera is designed to measure the poloidal profile of the plasma X-ray emission with high spatial and temporal resolutions and will be installed inside equatorial port 12. Due to the harsh environment of neutron and gamma radiations, nuclear radiation hardness of many components has to be considered in design and test, including silicon detector array, electronics, and cabling. As for electronics put in a port cell, a preliminary design of highly integrated preamplifier and program controllable midamplifier has been completed, and many tests have been done to investigate the radiation hardness performance of the amplifiers together with detectors. In the Cf-252 neutron test with flux of similar to 2.23 x 10(3) n.cm(-2).s(-1) and fluence greater than 1.0 x 10(10) n.cm(-2), there was no performance degradation in detector and preamplifier. In the Co-60 gamma test with a dose rate of 0.5 Gy.min(-1) and an accumulated dose of 200 Gy, the performance change was not found in preamplifier and midamplifier except for some radiation damage to the power module in the board of preamplifier. In the following accelerator neutron test where the neutron flux is similar to 5 x 10(7) n.cm(-2).s(-1) and neutron fluence is 2 x 10(12) n.cm(-2), the functional problem was not found in preamplifier and cable, while there were occurrences of single-event effect in mid-amplifier. The detector underwent 10% decrease of sensitivity to visible light. In addition, shielding cabinet was designed to provide good protection for electronics inside. |
关键词 | Amplifier radiation hardness X-ray camera |
DOI | 10.1109/TNS.2018.2849410 |
收录类别 | SCI |
语种 | 英语 |
资助项目 | National Nature Science Foundation of China[11605240] ; National Nature Science Foundation of China[11605243] ; National Nature Science Foundation of China[11605240] ; National Nature Science Foundation of China[11605243] |
项目资助者 | National Nature Science Foundation of China ; National Nature Science Foundation of China ; National Nature Science Foundation of China ; National Nature Science Foundation of China ; National Nature Science Foundation of China ; National Nature Science Foundation of China ; National Nature Science Foundation of China ; National Nature Science Foundation of China ; National Nature Science Foundation of China ; National Nature Science Foundation of China ; National Nature Science Foundation of China ; National Nature Science Foundation of China ; National Nature Science Foundation of China ; National Nature Science Foundation of China ; National Nature Science Foundation of China ; National Nature Science Foundation of China |
WOS研究方向 | Engineering ; Nuclear Science & Technology |
WOS类目 | Engineering, Electrical & Electronic ; Nuclear Science & Technology |
WOS记录号 | WOS:000444905200007 |
出版者 | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.hfcas.ac.cn:8080/handle/334002/39102 |
专题 | 中科院等离子体物理研究所 |
通讯作者 | Cao, H. |
作者单位 | Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China |
第一作者单位 | 中科院等离子体物理研究所 |
通讯作者单位 | 中科院等离子体物理研究所 |
推荐引用方式 GB/T 7714 | Hu, L.,Cao, H.,Zhao, J.,et al. Design and Test of Irradiation-Related Components in ITER Radial X-Ray Camera[J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE,2018,65(9):2398-2403. |
APA | Hu, L..,Cao, H..,Zhao, J..,Niu, L..,Chen, Y..,...&Zhang, S..(2018).Design and Test of Irradiation-Related Components in ITER Radial X-Ray Camera.IEEE TRANSACTIONS ON NUCLEAR SCIENCE,65(9),2398-2403. |
MLA | Hu, L.,et al."Design and Test of Irradiation-Related Components in ITER Radial X-Ray Camera".IEEE TRANSACTIONS ON NUCLEAR SCIENCE 65.9(2018):2398-2403. |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Hu, L.]的文章 |
[Cao, H.]的文章 |
[Zhao, J.]的文章 |
百度学术 |
百度学术中相似的文章 |
[Hu, L.]的文章 |
[Cao, H.]的文章 |
[Zhao, J.]的文章 |
必应学术 |
必应学术中相似的文章 |
[Hu, L.]的文章 |
[Cao, H.]的文章 |
[Zhao, J.]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论