Institutional Repository of Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, China
High Sensitivity Detection of Carbon Dioxide Based on Portable Cylindrical Multi-Pass Cell | |
Chen Jia-jin1,2; Wang Gui-shi1; Liu Kun1; Tan Tu1; Cheng Gang1; Tian Xing1; Gao Xiao-ming1,2 | |
2019 | |
发表期刊 | SPECTROSCOPY AND SPECTRAL ANALYSIS |
ISSN | 1000-0593 |
摘要 | Carbon dioxide is one of the most important greenhouse gases playing an important role in climate change and human activities, so the detection of carbon dioxide concentration has an important significance. Highly sensitive detection of carbon dioxide gas was achieved by using near infrared tunable diode laser absorption spectroscopy combined with self-designed portable miniaturized cylindrical mirror multi-pass absorption cell. The cylindrical mirrors multi-pass absorption cell was optimized and designed by using a light transmission matrix programmed with Matlab software, compared with traditional Herriott multipass cell, which has the advantages of high mirror utilization and longer optical path length in the same volume. An effective optical path length of 14 m was achieved with 15 cm physical length. In present work, a DFB diode laser emission at 1. 57 mu m was used as a light source. Direct absorption spectroscopy method was used to detect the CO2, and the Allan variance was used to analyze the system performance. The results showed that the detection sensitivity of the system can be achieved 5. 3 mu L.L-1 with the average time of 5 s, and a detection sensitivity of 33. 1 mu L.L-1 can be achieved by averaging in 235 s. In addition, CO2 in the atmosphere was measured by the developed CO2 sensor, the measured results showed that the concentration of CO2 in the atmosphere is about 383. 4 mu L.L-1 The tunable diode laser absorption spectroscopy (IDLAS) system based on cylindrical mirrors multi-pass absorption cell, combined with the cylindrical mirrors multi pass cell can achieve long optical path in a small volume and tunable diode laser absorption spectroscopy technology has the advantages of high sensitivity, high resolution and fast response, greatly reduces volume and improves detection sensitivity of the system, which has a broad application in the field of gas detection. |
关键词 | Tunable laser Direct absorption spectroscopy Optical multi-pass absorption cell Carbon dioxide Detection |
DOI | 10.3964/j.issn.1000-0593(2019)01-0292-05 |
关键词[WOS] | DIODE-LASER ; CO2 ; SPECTROSCOPY |
收录类别 | SCI |
语种 | 英语 |
WOS研究方向 | Spectroscopy |
WOS类目 | Spectroscopy |
WOS记录号 | WOS:000456357000045 |
出版者 | OFFICE SPECTROSCOPY & SPECTRAL ANALYSIS |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.hfcas.ac.cn:8080/handle/334002/41457 |
专题 | 中科院安徽光学精密机械研究所 |
通讯作者 | Wang Gui-shi; Gao Xiao-ming |
作者单位 | 1.Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Hefei 230031, Anhui, Peoples R China 2.Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China |
第一作者单位 | 中科院安徽光学精密机械研究所 |
通讯作者单位 | 中科院安徽光学精密机械研究所 |
推荐引用方式 GB/T 7714 | Chen Jia-jin,Wang Gui-shi,Liu Kun,et al. High Sensitivity Detection of Carbon Dioxide Based on Portable Cylindrical Multi-Pass Cell[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS,2019,39(1):292-296. |
APA | Chen Jia-jin.,Wang Gui-shi.,Liu Kun.,Tan Tu.,Cheng Gang.,...&Gao Xiao-ming.(2019).High Sensitivity Detection of Carbon Dioxide Based on Portable Cylindrical Multi-Pass Cell.SPECTROSCOPY AND SPECTRAL ANALYSIS,39(1),292-296. |
MLA | Chen Jia-jin,et al."High Sensitivity Detection of Carbon Dioxide Based on Portable Cylindrical Multi-Pass Cell".SPECTROSCOPY AND SPECTRAL ANALYSIS 39.1(2019):292-296. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
基于便携式柱面镜多通池的二氧化碳高灵敏度(817KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。