摘要The insulation performance of wet wrapping of terminal service box pipework is investigated by the Paschen discharge test in this study. The test mock-up was designed with a U-shaped pipework as the fundamental structure, consisting of insulator breaks, voltage taps, and high voltage wires. In addition, the design of the test mock-up and insulation structure is studied, and the investigation method used in this study is described in detail. A high voltage test was conducted at room temperature for various degrees of vacuum. The test results demonstrated that the insulation (wet wrapping) remains undamaged, and leakage current is less than 10 mu A. Further, the test results conformed to the requirements of the ITER Organization. Finally, the performance of the insulation was determined, and the feasibility of the wet wrapping process was verified indirectly.
关键词Paschen test Insulation Gas discharge Electrical test
DOI10.1016/j.fusengdes.2019.01.100
收录类别SCI
语种英语
资助项目ASIPP CC project team
项目资助者ASIPP CC project team ; ASIPP CC project team ; ASIPP CC project team ; ASIPP CC project team ; ASIPP CC project team ; ASIPP CC project team ; ASIPP CC project team ; ASIPP CC project team
WOS研究方向Nuclear Science & Technology
WOS类目Nuclear Science & Technology
WOS记录号WOS:000461408800004
出版者ELSEVIER SCIENCE SA
引用统计
被引频次:2[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.hfcas.ac.cn:8080/handle/334002/42381
专题中科院等离子体物理研究所
通讯作者Zheng, Wangwang
作者单位1.Univ Sci & Technol China, Hefei, Anhui, Peoples R China
2.Chinese Acad Sci, Inst Plasma Phys, Hefei, Anhui, Peoples R China
推荐引用方式
GB/T 7714
Zheng, Wangwang,Huang, Xiongyi,Zheng, Jinxing. Experimental results on Paschen tests on the electrical insulation of the terminal service Box of the correction coils of ITER[J]. FUSION ENGINEERING AND DESIGN,2019,140:23-26.
APA Zheng, Wangwang,Huang, Xiongyi,&Zheng, Jinxing.(2019).Experimental results on Paschen tests on the electrical insulation of the terminal service Box of the correction coils of ITER.FUSION ENGINEERING AND DESIGN,140,23-26.
MLA Zheng, Wangwang,et al."Experimental results on Paschen tests on the electrical insulation of the terminal service Box of the correction coils of ITER".FUSION ENGINEERING AND DESIGN 140(2019):23-26.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zheng, Wangwang]的文章
[Huang, Xiongyi]的文章
[Zheng, Jinxing]的文章
百度学术
百度学术中相似的文章
[Zheng, Wangwang]的文章
[Huang, Xiongyi]的文章
[Zheng, Jinxing]的文章
必应学术
必应学术中相似的文章
[Zheng, Wangwang]的文章
[Huang, Xiongyi]的文章
[Zheng, Jinxing]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。