Knowledge Management System of Hefei Institute of Physical Science,CAS
Hard X-ray PHA system on the HT-7 tokamak | |
其他题名 | Hard X-Ray PHA System on the HT-7 Tokamak |
2006-01-01 | |
发表期刊 | PLASMA SCIENCE & TECHNOLOGY
![]() |
ISSN | 1009-0630 |
摘要 | A new hard X-ray pulse-height analysis (PHA) system has been established on HT-7 tokamak for long pulse steady-state operation. This PHA system consists of hard X-ray diagnostics and multi-channel analysers (MCA). The hard X-ray diagnostics consists of a vertical X-ray detector array (CdTe) and a horizontal X-ray detector array (NaI). The hard X-ray diagnostics can provide the profile of power deposition and the distribution function of fast electron during radio frequency (RF) current drive. The MCA system is the electronic part of the PHA system, which has been modularized and linked to PC through LAN. Each module of MCA can connect with 8 X-ray detectors. The embedded Ethernet adapter in the MCA module makes the data communication between PC and MCA very convenient. A computer can control several modules of MCA through certain software and a hub. The RAM in MCA can store 1024 or more spectra for each detector and therefore the PHA system can be applied in the long pulse discharge of several minutes. |
其他摘要 | A new hard X-ray pulse-height analysis (PHA) system has been established on HT-7 tokamak for long pulse steady-state operation. This PHA system consists of hard X-ray diagnostics and multi-channel analysers (MCA). The hard X-ray diagnostics consists of a vertical X-ray detector array (CdTe) and a horizontal X-ray detector array (NaI). The hard X-ray diagnostics can provide the profile of power deposition and the distribution function of fast electron during radio frequency (RF) current drive. The MCA system is the electronic part of the PHA system, which has been modularized and linked to PC through LAN. Each module of MCA can connect with 8 X-ray detectors. The embedded Ethernet adapter in the MCA module makes the data communication between PC and MCA very convenient. A computer can control several modules of MCA through certain software and a hub. The RAM in MCA can store 1024 or more spectra for each detector and therefore the PHA system can be applied in the long pulse discharge of several minutes. |
关键词 | ION BERNSTEIN WAVE PHA tokamak hard X-ray MCA lower hybrid current driven (LHCD) |
收录类别 | CSCD |
语种 | 英语 |
CSCD记录号 | CSCD:2658827 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.hfcas.ac.cn:8080/handle/334002/65224 |
专题 | 中国科学院合肥物质科学研究院 |
推荐引用方式 GB/T 7714 | . Hard X-ray PHA system on the HT-7 tokamak[J]. PLASMA SCIENCE & TECHNOLOGY,2006,8. |
APA | (2006).Hard X-ray PHA system on the HT-7 tokamak.PLASMA SCIENCE & TECHNOLOGY,8. |
MLA | "Hard X-ray PHA system on the HT-7 tokamak".PLASMA SCIENCE & TECHNOLOGY 8(2006). |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
百度学术 |
百度学术中相似的文章 |
必应学术 |
必应学术中相似的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论