口服泛影葡胺对宫颈癌容积旋转调强放疗剂量分布的影响
其他题名Effects of oral diatrizoate on the dose distribution of volumetric modulated arc therapy for cervical cancer
2019-01-01
发表期刊中国医学物理学杂志
ISSN1005-202X
摘要目的:探讨口服泛影葡胺溶液对宫颈癌容积旋转调强放疗剂量分布的影响。方法:选择12例口服泛影葡胺溶液的宫颈癌患者的CT图像,设计容积旋转调强放疗计划。采用相同CT图像,更改肠造影区CT值为常规肠内容物CT值,并保持其他参数不变,将VMAT计划移植到改变了CT值的CT图像上,重新计算剂量分布。借助肿瘤靶区和危及器官分析肠造影区CT值改变前后剂量分布的差异。结果:肠造影区CT值改变前后,计划靶区适形度和均匀度的比较显示差异无统计学意义(P>0.05);计划靶区最小和最大剂量相对百分比分别为0.07和0.15(P=0.32,0.59),而平均剂量差异为0.09(P=0.00)。危及器官中仅肠的剂量分布有显著统计学差异,其V40、V30和V20相对百分比分别为0.11、0.16和0.03(P=0.03,0.03,P=0.03)。结论:口服泛影葡胺溶液对宫颈癌靶区的平均剂量及肠剂量分布的影响有显著统计学意义。但从临床分析结果来看,口服泛影葡胺溶液造成剂量分布的绝对差异可忽略。
其他摘要Objective To discuss the effects of oral diatrizoate on the dose distribution of volumetric modulated arc therapy (VMAT) for cervical cancer. Methods The CT images of 12 cervical cancer patients after taking oral diatrizoate were selected and VMAT (Plan A) was designed for each patient. Based on the same CT images, the CT value of contrast area in intestine was changed to the value of intestinal content, and the other parameters remained unchanged. The VMAT plan was transplanted on the CT image with the CT value of intestinal content (Plan B), and the dose distribution was re-calculated. The dosimetric differences were analyzed by assessing the deviation of dose distribution of target areas and organs-at-risk between PlanAand Plan B. Results Both Plan A and Plan B had similar conformity index and homogeneity index of target areas (P>0.05). The relative percentages of minimum dose, maximum dose and mean dose between Plan Aand Plan B was 0.07, 0.15 and 0.09, respectively (P=0.32, 0.59, 0.00). For the dosimetirc parameters of organs-at-risk, statistical differences were only found in intestine, and the relative percentage of the V40, V30 and V20 of intestine were 0.11, 0.16 and 0.03, respectively (P=0.03, 0.03, 0.03). Conclusion The effect of oral diatrizoate on dose distribution was statistically significant for both the mean dose of planning target areas and the dose distribution of intestine. However, the clinical analysis reveals that the absolute differences of dose distribution caused by oral diatrizoate can be neglected.
关键词宫颈癌 容积旋转调强 口服泛影葡胺溶液 剂量分布
收录类别CSCD
语种中文
CSCD记录号CSCD:6498554
引用统计
文献类型期刊论文
条目标识符http://ir.hfcas.ac.cn:8080/handle/334002/65374
专题中国科学院合肥物质科学研究院
推荐引用方式
GB/T 7714
. 口服泛影葡胺对宫颈癌容积旋转调强放疗剂量分布的影响[J]. 中国医学物理学杂志,2019,036.
APA (2019).口服泛影葡胺对宫颈癌容积旋转调强放疗剂量分布的影响.中国医学物理学杂志,036.
MLA "口服泛影葡胺对宫颈癌容积旋转调强放疗剂量分布的影响".中国医学物理学杂志 036(2019).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
百度学术
百度学术中相似的文章
必应学术
必应学术中相似的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。