摘要Under the condition of steady,the pressure drop of coolant is mainly caused by friction along the cable.in the CICC(cable-in-conduit-conductor).helium flow within the conductor consists of two parallel interconnected tubes.The velocity distribution has some differece between the central channel and conductor space.The region of Reynolds number is from 10^3 to 10^6.This paper describes the calculation of pressure drop of HT-7U CICC at various mass flows.It is assumed that the coolant flows in two parallel,rough tudes during the caclulation.
其他摘要Under the condition of steady,the pressure drop of coolant is mainly caused by friction along the cable.in the CICC(cable-in-conduit-conductor).helium flow within the conductor consists of two parallel interconnected tubes.The velocity distribution has some differece between the central channel and conductor space.The region of Reynolds number is from 10~3 to 10~6.This paper describes the calculation of pressure drop of HT-7U CICC at various mass flows.It is assumed that the coolant flows in two parallel,rough tudes during the caclulation.
关键词等离子体物理学 超导体Tokamak 稳定压降
收录类别CSCD
语种中文
CSCD记录号CSCD:1362109
引用统计
文献类型期刊论文
条目标识符http://ir.hfcas.ac.cn:8080/handle/334002/66824
专题中国科学院合肥物质科学研究院
推荐引用方式
GB/T 7714
. A Calculation of Steady Pressure Drop and an Analysis of HT—7U CICC[J]. 等离子体科学和技术:英文版,2002,004.
APA (2002).A Calculation of Steady Pressure Drop and an Analysis of HT—7U CICC.等离子体科学和技术:英文版,004.
MLA "A Calculation of Steady Pressure Drop and an Analysis of HT—7U CICC".等离子体科学和技术:英文版 004(2002).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
百度学术
百度学术中相似的文章
必应学术
必应学术中相似的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。