Institutional Repository of Chinese Academy of Sciences, Institute of Plasma Physics, Hefei 230031, Anhui, Peoples R China
HT-7超导托卡马克上辐射剂量测量与分析 | |
其他题名 | MEASUREMENT AND ANALYSIS OF RADIATION DOSES ON HT-7 SUPERCONDUCTING TOKAMAK |
陈珏铨; 朱玉宝; 张 卫 | |
2006 | |
发表期刊 | 辐射防护
![]() |
ISSN | 1000-8187 |
摘要 | HT-7超导托卡马克是我国正在运行中的中型准稳态磁约束聚变实验研究装置,运行时产生一个复杂的瞬发混合辐射场。本文介绍了该装置上中子辐射剂量率的测量方法以及在欧姆、波辅助加热、长脉冲等放电模式下的剂量率特点,并且给出了X与7射线的总辐射剂量测量方法和分析结果。在严格遵守安全操作规程的前提下,目前的等离子体物理实验对人员产生的总辐射剂量低于国家辐射安全标准的规定。 |
合作性质 | 其它 |
其他摘要 | HT-7 Tokamak is a middle sized magnetic confinement fusion device in operation. It produces a complicated mixed prompt radiation field when working. Briefly introduces the measuring method for neutron dose rate on HT-7, and presents the neutron radiation characteristics under Ohmic, wave heating and long pulse operation mode. The measuring methods of X and y ray radiation doses and the analysis results are also presented. Following the regulations strictly, the total personal radiation dose received in the plasma experiments are lower than national safety standards. |
关键词 | 托卡马克 辐射剂量 中子 X与γ射线 |
学科领域 | 聚变装置系统 |
收录类别 | 其他 |
语种 | 中文 |
CSCD记录号 | CSCD:2327349 |
文献类型 | 期刊论文 |
条目标识符 | http://ir.hfcas.ac.cn:8080/handle/334002/755 |
专题 | 中科院等离子体物理研究所 |
推荐引用方式 GB/T 7714 | 陈珏铨,朱玉宝,张 卫. HT-7超导托卡马克上辐射剂量测量与分析[J]. 辐射防护,2006,026(2). |
APA | 陈珏铨,朱玉宝,&张 卫.(2006).HT-7超导托卡马克上辐射剂量测量与分析.辐射防护,026(2). |
MLA | 陈珏铨,et al."HT-7超导托卡马克上辐射剂量测量与分析".辐射防护 026.2(2006). |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
HT-7超导托卡马克上辐射剂量测量与分析(270KB) | 开放获取 | 使用许可 | 浏览 下载 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[陈珏铨]的文章 |
[朱玉宝]的文章 |
[张 卫]的文章 |
百度学术 |
百度学术中相似的文章 |
[陈珏铨]的文章 |
[朱玉宝]的文章 |
[张 卫]的文章 |
必应学术 |
必应学术中相似的文章 |
[陈珏铨]的文章 |
[朱玉宝]的文章 |
[张 卫]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论