HFCAS OpenIR
过冷态超流氦恒温器的热力学分析
其他题名Thermodynamic analysis of subcooled superfluid helium cryostat
朱志刚1; 庄明1; 刘华军1; 郝强旺1
2013
发表期刊低温工程
ISSN1000-6516
摘要对过冷态超流氦恒温器的热力学过程进行分析,考察了不同的设计温度和J-T换热器热效率下恒温器的制冷性能,得到了理论制冷量的变化曲线。结果表明,理论制冷量与设计温度和J-T换热器的热效率密切相关。计算发现,160 L液氦在2 W制冷量下从4.2 K降至1.8 K大约需要24 h。
其他摘要Thermodynamic analysis of subcooled superfluid helium cryostat was carried out.The influence of different design temperature and different efficiency of J-T heat exchanger on theoretical cooling capacity was analyzed,and theoretical cooling capacity variation curves were also presented.The results show that theoretical cooling capacity is greatly related to design temperature and efficiency of J-T heat exchanger.It will take about 24 h to cool 160 L liquid helium from 4.2 K down to 1.8 K with 2 W cooling capacity.
关键词超流氦 低温恒温器 热力学分析
收录类别CSCD
语种中文
CSCD记录号CSCD:4858309
引用统计
文献类型期刊论文
条目标识符http://ir.hfcas.ac.cn:8080/handle/334002/93026
专题中国科学院合肥物质科学研究院
作者单位1.中国科学院等离子体物理研究所
2.中国科学院等离子体物理研究所
3.中国科学院等离子体物理研究所
4.中国科学院等离子体物理研究所
推荐引用方式
GB/T 7714
朱志刚,庄明,刘华军,等. 过冷态超流氦恒温器的热力学分析[J]. 低温工程,2013,000.
APA 朱志刚,庄明,刘华军,&郝强旺.(2013).过冷态超流氦恒温器的热力学分析.低温工程,000.
MLA 朱志刚,et al."过冷态超流氦恒温器的热力学分析".低温工程 000(2013).